PHOTOCELL PM001

Encapsulated photoelectric relay intended for areas classified with the presence of flammable vapors and gases, its operation is switched according to the variation of the incident light. The photoelectric relay has a great differential. In addition to its modern and effective design, its electronic circuit was dimensioned with a protection system against transient flashes. Can be installed in Zone 1 (including explosion-proof), Zone 2, Zone 21 and Zone 22 luminaires and enclosures, for groups IIA, IIB, IIC, IIIA, IIIB, IIIC. Certified according to Inmetro (Brazil). The connection is made through an explosion-proof component with the M22x1.5 or 3/4"NPSM thread.

  • CERTIFICATION: Inmetro.
  • APPLICATION: Zones 1, 2, 21, 22, Groups IIA, IIB, IIC, IIIA, IIIB, IIIC.
  • TYPE OF PROTECTION: Ex d (flameproof), Ex tb (dust ignition protection).
  • INGRESS PROTECTION: IP66.
  • AVAILABLE THREADS: M22x1,5 or 3/4"NPSM. 
  • NOMINAL VOLTAGE: 115/230 Vac.
  • MAXIMUM POWER: 1,0 kW (mixed lamps), 1,8 kVA (loads with FP<1).
  • POWER CONSUMED EMPTY: < 1,0 W.
  • TDS - PHOTOCELL PM